Tesamorelin dosing chart (mg to units)

Tesamorelin's 2 mg vial amount comes from a prescribing-label source in PinPoint's library. Its description identifies a stabilized GHRH analog, and the peptide record carries an FDA-approved research-status tag. The amount table translates portions of that 2 mg total into volume. The cited prescribing information is for Egrifta SV.

Vial concentration

Water mL is treated as final solution mL in these columns.

Tesamorelin: concentration in mg per mL
Vial contents1 mL water2 mL water3 mL water
2 mg2 mg/mL50 U-100 units per mg1 mg/mL100 U-100 units per mg0.6667 mg/mL150 U-100 units per mg

Vial source: PinPoint/Data/CompoundLibrary.swift, line 765, the Tesamorelin entry. One documented amount is available.

Amount to units

Example amounts (arithmetic only, not doses).

Tesamorelin: amount to U-100 syringe units
Amount (mg)2 mg + 1 mL2 mg + 2 mL2 mg + 3 mL
0.04 mg2 units4 units6 units
0.1 mg5 units10 units15 units
0.2 mg10 units20 units30 units
0.4 mg20 units40 units60 units
1 mg50 units100 units150 unitsover one syringe

Cited amounts

Tesamorelin: source amounts converted using this page's vial and water columns
Amount (mg) and source contextFrequency as statedRoute as stated2 mg + 1 mL2 mg + 2 mL2 mg + 3 mLSource
1.4 mgSpecific 2 mg/vial formulation; source preparation is 0.5 mL with a 0.35 mL administration, distinct from these arithmetic columns. Once dailySubcutaneous 70 units140 unitsover one syringe210 unitsover one syringe Tesamorelin prescribing information (Egrifta SV)Regulatory labelRetrieved 2026-10-05

How to read this chart

Find the concentration column. Divide the amount by that concentration. Multiply the mL value by 100 for U-100 units. Match the amount units before dividing.

units = amount ÷ (vial mg ÷ water mL) × 100

Amount and volume

One mg equals 1,000 mcg; 100 U-100 units equals 1 mL. Concentration connects amount to volume. Read the full conversion guide.

Nine minutes is an elimination parameter

PinPoint stores 0.15 hours as tesamorelin's half-life, equivalent to nine minutes. The source annotation ties the reference to prescribing-label information. This short value sets the elimination timescale of the base model; it is not a calendar interval for logging. The common-frequency field separately reads Once daily. A timestamp therefore places a short modeled event within a much longer daily record. The app can retain both the day-level sequence and the more detailed clock time without treating those two scales as interchangeable.

Why the peak-time field is a different number

The tesamorelin entry uses a 0.25-hour peak-time parameter, or 15 minutes, alongside a bioavailability coefficient of 0.04, or 4%. The peak input is longer than the stored nine-minute half-life. That arrangement reflects the separate roles of absorption and elimination in the model; a half-life is not a countdown from logging to the peak. These values describe the base compound profile, while an individual log supplies the event's amount and timestamp. None of the three model fields is a concentration in mg per mL.

Subcutaneous context and a label-based package

Subcutaneous is the route listed for tesamorelin, and the library uses a compounded-vial delivery form for its generic record. The package citation specifically documents 2 mg in a single-dose vial. In this collection, that label-based amount stands apart from the many vial totals obtained from supplier catalogs. The research-status tag, delivery-form field, and package citation each describe a different aspect of the entry. Reading them together explains why this page uses a 2 mg reference instead of borrowing a larger peptide vial size.

The one-milligram-per-milliliter column

When 2 mg is represented in a final volume of 2 mL, concentration is exactly 1 mg per mL. The tesamorelin example rows of 0.04, 0.1, 0.2, 0.4, and 1 mg then occupy those same numerical amounts in mL. For instance, 0.2 mg becomes 0.2 mL, corresponding to 20 U-100 units. This numerical match belongs to that one concentration. At a 1 mL total volume, the 0.2 mg portion is 0.1 mL; at 3 mL total, it is 0.3 mL.

Questions about the conversion

What concentration is Tesamorelin at 2 mg in 1 mL?

2 mg divided by 1 mL is 2 mg per mL. That volume spans 100 U-100 syringe units.

How does 2 mL change the concentration of this Tesamorelin vial?

2 mg divided by 2 mL is 1 mg per mL, half the concentration in the 1 mL column.

What does the 3 mL column mean for Tesamorelin?

2 mg divided by 3 mL is approximately 0.6667 mg per mL. The full 3 mL volume corresponds to 300 U-100 units.

How many units is 0.2 mg of Tesamorelin from this vial in 2 mL?

0.2 mg divided by 1 mg per mL is 0.2 mL, or 20 U-100 units.

How many units is the 1.4 mg cited amount of Tesamorelin from a 2 mg vial in 2 mL?

The arithmetic is 1.4 mg ÷ 1 mg/mL × 100 = 140 U-100 units (1.4 mL). The amount is cited in Tesamorelin prescribing information (Egrifta SV). Specific 2 mg/vial formulation; source preparation is 0.5 mL with a 0.35 mL administration, distinct from these arithmetic columns. This exceeds one 1 mL syringe.

Track your calculations in the app

PinPoint for iOS brings vial setup, unit conversion, dose logs, site rotation, and protocol tracking together. Enter vial size and water volume for concentration and syringe units, then log injections with compound, dose, site, and pain level.

Get PinPoint on the App Store